Parameters and Programming
Restoring Factory Defaults
This example shows you how to reset the factory defaults of the drive.
Action
Press Down Arrow to advance to the b parameter
group.
Press PROGram to enter into the b parameter
PROG
group.
Press Up Arrow to scroll through the parameters
until b84 [
Press PROGram to view the parameter value stored
PROG
in b84 - [
01. If it is not 01, use Up Arrow to change the value
to 01, then press Enter.
Note: The defaults will be reset to the values
determined by b85 [
Press PROGram to return to the parameter number
PROG
without changing the stored value.
Press and hold PROGram, Up Arrow, Down Arrow,
and Stop for 3 seconds.
PROG
Release the Stop Key and continue to hold the
PROGram, Up Arrow, and Down Arrow until the
PROG
display begins to blink. Release the remaining keys.
When this is done, 0.0 will be displayed (this is d01
[
OUTPUT FREQUENCY
Description
] is displayed.
RESET FUNCTIONS
] and verify that it is set to
RESET FUNCTIONS
FACTORY DEFAULT SELEC
].
English
Display
b--
b01
b84
01
t].
b84
b84
0.0