Parameter
Number
Communications
C70
Communication Command Select
Selects the source of the communication command.
Settings: 02 = Remote Operator
03 = RS422
C71
Baud Rate
Selects the Baud Rate for RS422 communication.
Settings: 04 = 4800 bps
05 = 9600 bps
06 = 19200 bps
C72
Drive Address
Sets the drive node address on the RS422 network.
C79
Communication Error Select
Selects the drives operation when a communication
error (E60) occurs.
Settings: 00 = Fault
01 = No Fault and continue operation
C91
Debug Mode
Used by Rockwell Automation field service personnel.
!
C92 - C95 [Reserved]
Reserved for future use. Do not change.
Parameters and Programming
Parameter Name/Description
ATTENTION: If C91 [
DEBUG MODE
to 01, parameters C92 to C95 are
enabled. Do not change parameters C91
to C95. Failure to observe this precaution
could result in personal injury
Min./Max
Range
02 to 03
04 to 06
01 to 32
00 to 01
00 to 01
] is set
00 to 01
English
Factory
Units
Default
Numeric
02
Value
Numeric
04
Value
N/A
01
Numeric
00
Value
Numeric
00
Value
Numeric
00
Value
3-21