Technical Data - Hitecsa 105 Manual De Instrucciones De Uso, Mantención E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. TECHNICAL DATA

Model
Application radiant panels
Nominal heating capacity (1)
COP (1)
Nominal heating capacity(1) EN 14511:2011
COP (1) EN 14511:2011
Nominal heating capacity (2)
COP (2)
COP (2) EN 14511:2011
Nominal power cooling (3)
EER (3)
Nominal power cooling (3) EN 14511:2011
EER (3) EN 14511:2011
Application fan
Nominal heating capacity (4)
COP (4)
Nominal heating capacity (4) EN 14511:2011
COP (4) EN 14511:2011
Nominal power cooling (5)
EER (5)
Nominal power cooling (5) EN 14511:2011
EER (5) EN 14511:2011
ESEER EN 14511:2011
Sound power (7)
Sound pressure (6)
Compressor
Fan
Air flow rate
Heat exchanger nominal flow water side (5)
Circulator available head pressure (5)
Coolant filling R410A
Polyester oil charge
Electrical data
Absorbed power in winter operation (1)
Absorbed power in winter operation (2)
Absorbed power in winter operation (4)
Power consumption in cooling operation (3)
Power consumption in cooling operation (5)
Electrical power supply
Auxiliary power supply
Power consumption circulator
Nominal current (1)
Nominal current (4)
Nominal current (3)
Nominal current (5)
Maximum current
Dimensions
Width (L)
Height (H)
Depth (P)
Water connections
Weight
Data referred to the following conditions:
1.
In the following conditions: evaporator inlet air temperature 7°C B.S., 6°C B.U.; hot water temperature 35°C; differential temperature at the evaporator 5°C.
2.
In the following conditions: evaporator inlet air temperature -7°C B.S., 6°C B.U.; hot water temperature 35°C to the same extent of the condition (1).
3.
In the following conditions: condenser inlet air temperature 35°C; refrigerated water temperature 18°C; differential temperature at the evaporator 5°C.
4.
In the following conditions: evaporator inlet air temperature 7°C B.S., 6°C B.U.; hot water temperature 45°C; differential temperature at the evaporator 5°C.
5.
In the following conditions: condenser inlet air temperature 35°C; refrigerated water temperature 7°C; differential temperature at the evaporator 5°C.
6.
Sound pressure level in dB(A) referring to measurement at 5 m from the unit, with directional factor equal to 2.
7.
Sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614 and Eurovent 8/1.
ESEER (European Seasonal EER) - European average seasonal energy efficiency
Section I :: User
105
kW
6,57
4,15
kW
6,48
4,34
kW
4,75
2,61
2,70
kW
5,09
3,68
kW
5,18
4,02
kW
6,26
3,03
kW
6,18
3,12
kW
3,75
2,72
kW
3,84
2,98
4,00
dB(A)
60
dB(A)
35
1
3
m
/h
3760
l/min
10,75
kPa
85
kg
1,05
kg
kW
1,59
kW
1,82
kW
2,07
kW
1,38
kW
1,38
V-ph-Hz
V-ph-Hz
kW
0,13
A
7,3
A
9,5
A
6,3
A
6,3
A
11,2
mm
898
mm
675
mm
300
3/4 "
Ø
kg
52
10
110
10,00
4,38
9,87
4,58
6,61
2,64
2,70
7,20
3,40
7,30
3,61
9,84
3,36
9,75
3,44
5,45
2,74
5,53
2,91
3,35
62
37
Hermetic Scroll
1
3600
15,62
55
1,72
See compressor plate
2,28
2,51
2,93
2,12
1,99
230-1- 50
230-1- 50
0,1
10,4
13,4
9,7
9,1
17,5
850
882
330
1 "
74
EN
116
16,19
4,04
16,00
4,20
10,82
2,71
2,80
15,92
3,70
16,11
3,91
15,40
3,30
15,20
3,40
12,40
2,81
12,60
3,00
3,90
63
38
2
7788
35,53
90
2,99
4,01
3,99
4,67
4,30
4,41
0,17
18,3
21,4
19,6
20,6
25,3
1000
1418
330
1-1/4 "
118

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

110116

Tabla de contenido