The TYRE CHANGER must be powered with three-phase current plus a neutral wire.
The power supply voltage must be specified in the purchase order.
WARNING
Any operations to hook up to the electrical board of the workshop must only be carried
out by qualified personnel, in accordance with the regulations of the current laws,
and this is the duty and responsibility of the customer.
- The electrical hook-up must be performed according to:
• absorbed power specifications indicated on the machine dataplate.
• the distance between the machine and the power supply hook-up point, so that voltage
drops under full load do not exceed 4% (10% during start-up) compared with the rated
voltage specified on the data plate.
- The operator must:
• a dedicated power plug in compliance with the relevant electrical safety standards.
• connect the machine to its own electrical connection fitted with a suitable differential
circuit breaker with 30mA sensibility and an intervention threshold of 100mA and a 32A
automatic thermal magnetic switch with a "D" type intervention curve.
• mount power line protection fuses, suitably sized according to the specifications indi-
cated on the main wiring diagram contained in this manual.
• prepare a suitable earthing system installed on the workshop mains line.
- prevent unauthorised use of the machine, always disconnect the power supply plug
when the machine is not used (switched off) for extended periods of time.
-
If the machine is connected directly to the power supply by means of the main
electrical panel and without the use of a plug, a key-operated or padlockable switch
must be installed to restrict machine use exclusively to qualified personnel.
WARNING
For the machine correct functioning it is vital to have a good ground connection.
NEVER connect the machine ground wire to a gas pipe, water pipe, telephone cable
or any other unsuitable object.
- E
- Operator's manual
nGlISH
ELECTRICAL HOOK-UP
59