n
o hydrauliC preSSure
Pump broken
• Replace the pump
e
xCeSSive Control unit noiSe
Worn connection joint
• Replace the joint
J
erky MoveMentS
Not enough oil
• Top up the oil
Switch on control lever defective
• Replace the switch
p
reSenCe oF radio interFerenCe
Identify and remove the source of the radio disturbance
Contact technical assistance to change the transmission channel
Simultaneous movement of 2 cylinders; a solenoid valve is probably locked
• Clean or replace the solenoid valve
e
.
xCeSSive trolley ClearanCe
• Contact technical service to adjust the sliding blocks
S
t
S
ide
o
ide doeS not Stop or doeS not Work
• Check that the diameter shown on the display corresponds to the rim diameter
• Clean the protective glass on the laser
• If there is an error message on the display contact technical assistance
• Contact Technical Assistance
t
he deMounting MoveMent doeS not Work
• Make sure the tool is in the horizontal position
• Check that the microswitch wire is connected
• If there is an error message on the display contact technical assistance
• Contact Technical Assistance
t
he diSC and tool tangenCy FunCtionS appear to have loSt their Calibration
• Delete the set memory
• Check that the diameter shown on the display corresponds to the rim diameter
• Contact Technical Assistance
W
,
hen turning on the Cold MaChine
quiCk tranSlation doeS not Work Well
• heat up the oil for a few minutes by moving the machine at a normal speed.