2. The operator must always wear a helmet with a protective
visor, waterproof gear and wear boots that are appropriate
for use and can ensure a good grip on wet floors.
Note: appropriate clothing will protect against sprays of water
but not from direct impact with jets of water or very close sprays.
Additional protections may therefore be necessary in certain
circumstances.
3. It is good practice to organize personnel into teams of at
least two people capable of giving mutual and immediate
assistance in case of necessity and of taking turns during
long and demanding operations.
4. The work area jet range must be absolutely prohibited to
and free from objects that, inadvertently under a pressure
jet, can be damaged and/or create dangerous situations.
5. The water jet must always and only be pointed in the
direction of the work area, including during preliminary
tests or checks.
6. The operator must always pay attention to the trajectory
of debris removed by the water jet. Where necessary,
suitable guards must be provided by the Operator to
protect anything that could become accidentally exposed.
7. The operator should not be distracted for any reason
during work. Workers needing to access the operating area
must wait for the Operator to stop work on his/her own
initiative, after which they should immediately make their
presence known.
8. It is important for safety that all team members are always
fully aware of each other's intentions in order to avoid
dangerous misunderstandings.
9. The high pressure system must not be started up and run
under pressure without all team members in position and
without the Operator having already directed his/her lance
toward the work area.
3.5
Safety during system maintenance
1. High pressure system maintenance must be carried out
in the time intervals set by the manufacturer who is
responsible for the whole group according to law.
2. Maintenance should always be performed by trained and
authorized personnel.
3. Assembly and disassembly of the pump and the various
components must only be carried out by authorized
personnel, using appropriate equipment in order
to prevent damage to components, in particular to
connections.
4. Always only use original spare parts to ensure total
reliability and safety.
4
PUMP IDENTIFICATION
Each pump has its own Serial No. XX.XXX.XXX see pos. and
an identification plate see pos. in Fig. 1 which shows:
-
Pump model and version
-
Max revs
-
Absorbed power HP - kW
-
Flow rate l/min - Rpm
-
Pressure bar- PSI
2
3
Modello
R.P.M.
kW/Cv
2
l .min/GPM
bar/PSI
DIVISIONE DI INTERPUMP
Modello
R.P.M.
kW/Cv
2
Matricola
l.min/GPM
bar/PSI
I NTERPUMP
G RO UP
For pumps ordered with the ATEX configuration.
Pos. plate with specific ATEX marking for
explosion protection.
Pos. plate for locating the grounding screw.
Model, version and serial number must always be
indicated when ordering spare parts
23
1
XX.XXX.XXX
4
INLET WATER
MAX. 40°C
F/T: 70-ATX
II 2G Ex h IIC T4 Gb
II 2D Ex h IIIC T135°C Db
Interpump Group S.p.A. Via Fermi, 25
S.Ilario 42049 (RE) - ITALY
98287400
GROUP S.P.A.
MADE IN ITALY
4
98.2887.00
MADE IN ITALY
Fig. 1