To carry out this operation, proceed as follows.
Important
Before proceeding, allow the appliance to
cool for 10÷15 min., so that the oil reaches
a temperature between 50÷120.
1 - Open the hatch (A).
2 - Fit the extension (B) onto the tap (C).
3 - Place the container (D) and the filter (E), both
available as optionals, underneath the exten-
sion (B).
4 - Turn on the tap (C) to empty the well.
5 - Turn off the tap (C) on completion of the opera-
tion.
6 - Close the hatch (A).
Caution - warning
Do not dump oil in the environment; dis-
pose of it in accordance with the laws in
force in the country of use.
Safety thermostat
If the safety thermostat is tripped, the appliance has
IT
to be restored to the initial working conditions as fol-
lows.
1 - Allow the oil to cool to 30÷40°C.
GB
2 - Open the hatch (A).
3 - Press the button (B) of the safety thermostat
DE
tripped to restore the gas supply.
Important
FR
To identify the thermostat that has been
tripped, check which burner has cut out
ES
and press the corresponding button.
4 - Close the hatch (A).
Combustion control unit
If the combustion control unit is tripped, the appli-
ance has to be restored to the initial working condi-
tions as follows.
1 - Press the button (C) Reset Gas to restore the
gas supply.