TECHNICAL DATA
See tables and "Connection chart" at the back of
the manual.
SAFETY DEVICES
Although the appliance is complete with all safety
devices, during installation and connection addi-
tional devices must be added if necessary to com-
ply with the relevant legal requirements.
The illustration shows the position of the devices.
A)Gas supply tap: for turning the connection to the
gas supply line on and off.
B)Combustion control unit: cuts off the gas supply if
the flame goes out..
C)Safety thermostat: cuts off the gas supply in case
of overheating.
Caution - warning
Make a daily check that the safety devices are
properly installed and in good working order.
SAFETY AND INFORMATION SIGNS
The illustration shows the position of the signs pro-
vided.
A)Nameplate with manufacturer and appliance
data.
B)General hazard: read the manual carefully before
carrying out any procedure.
C)General hazard: when washing the appliance do
not point pressurised water jets at internal parts.
C
B
C
D)General hazard: all relevant regulations must be
complied with. "Install in compliance with the rele-
vant regulations and use in well ventilated premises
only".
E)General hazard: all relevant regulations must be
complied with. "No liability is accepted in case of fail-
ure to comply with the installation and commission-
ing instructions".
- 5 -
091FR1I
A
191FR2I
C
B
A
IDM-39619400200.tif
IT
GB
DE
FR
ES
English