ADJUSTING BURNER PRIMARY AIR

To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Open the hatch (A).
3 - Undo the locking screw (B).
4 - Set the bush (C) at the distance as shown in the
figure.
5 - Tighten the screw (B).
After making the setting, seal the screw with
paint.
6 - Close the door (A) when the operation is com-
plete.
RECOMMENDATIONS FOR REPLACING PARTS
Before carrying out any replacement procedure, ac-
tivate all the safety devices provided and decide
whether staff at work and those in the vicinity
should be informed. In particular, turn off the gas
supply tap and prevent access to all devices which
might cause unexpected health and safety hazards
if turned on. If work parts have to be replaced, use
original spare parts only.

REPLACEMENT OF THE BURNER NOZZLE

To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Open the hatch (A).
3 - Unscrew the nozzle (B) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
4 - Close the door (A) when the operation is com-
plete.

REPLACING PARTS

- 23 -
A
The manufacturer declines all responsibly for
injury or damage to components due to the use of
non original parts, or extraordinary work on the ap-
pliance which may modify the safety requirements
without the manufacturer's authorisation. When or-
dering components, follow the instructions provided
in the parts catalogue.
A
B
C
29±1mm
IDM-39615301500.tif
9
B
B
IDM-39615301800.tif
English