Installation; Installation Requirements; Electrode Axis; In- And Outlet Pipe Sections - ABB FXE4000 COPA-XE Instrucciones Para La Puesta En Funcionamiento

Ocultar thumbs Ver también para FXE4000 COPA-XE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 99
3

Installation

Wechsel ein-auf zweispaltig
3.1

Installation Requirements

The device measures the flowrate in both directions. The factory
default is forward flow, as shown in Fig. 3.
Fig. 3
The following items must be observed:
3.1.1

Electrode axis

Electrode axis (1) should be horizontal if at all possible or no more
that 45° from horizontal.
Fig. 4
3.1.2

In- and outlet pipe sections

Straight inlet section
≥ 3 x DN
DN = Flowmeter primary size
Do not install fittings, manifolds, valves etc. directly in front of the
meter tube (1).
Butterfly valves must be installed so that the valve plate does not
extend into the flowmeter primary.
Valves or other turn-off components should be installed in the
outlet pipe section (2).
For compliance with the measuring accuracy, observe the inlet
and outlet pipe sections.
1
Fig. 5
Wechsel ein-auf zweispaltig
D184B133U02
G00156
max. 45°
1
G00041
Straight outlet section
≥ 2 x DN
2
2xDN
3xDN
G00037
FXE4000 (COPA-XE/MAG-XE)
3.1.3

Vertical connections

Vertical installation for measurement of abrasive fluids, flow
preferably from below to above.
Fig. 6
3.1.4

Horizontal connections

Meter tube must always be completely full.
Provide for a slight incline of the connection for degassing.
Fig. 7
3.1.5

Free inlet or outlet

Do not install the flowmeter at the highest point or in the draining-
off side of the pipeline, flowmeter runs empty, air bubbles can
form (1).
Provide for a siphon fluid intake for free inlets or outlets so that
the pipeline is always full (2).
1
Fig. 8
3.1.6

Installation in the vicinity of pumps

For flowmeter primaries which are to be installed in the vicinity of
pumps or other vibration generating equip-ment, the utilization of
mechanical snubbers is advantageous.
Fig. 9
Installation
G00039
G00038
2
G00040
G00043
EN - 9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fxe4000 mag-xe

Tabla de contenido