8.1 | Electrical connection

CAUTION
Material breakage.
Risk of falling. Risk of impact due to the pos-
sibility of products falling. Cutting injuries.
▪ Do not climb onto or into the unit.
NOTICE
Material and property damage in the event of
incorrect positioning.
▪ Place the appliance in a stable operating position
(horizontal alignment).
▪ Do not expose the unit to direct heat radiation at the
installation site.
▪ Do not expose the device at the installation site to
the direct action of air conditioning and ventilation.
▪ Do not install the appliance outdoors.
Material and property damage due to accumu-
lation of warm exhaust air (heat accumula-
tion).
▪ Exhaust air must be able to escape unhindered at
the top and rear of the appliance.
▪ Maintain a minimum distance from the wall. The
minimum distance is defined by wall spacers on the
rear of the appliance.
▪ Only operate the appliance with wall spacers.
▪ "Back to back" installation only in consultation with
the manufacturer.
Wall spacer mounting
Wall spacer is included with the appliance as an ac-
cessory pack.
– Attach the wall spacer to the four pre-installed
screws.
1
Fig. 4: Wall spacer (1) on rear of appliance
Install display shelves
CAUTION
Improper installation of the display
shelves.
Risk of injury due to falling of the display
shelves holding goods.
▪ The bracket for the display shelves and the
display shelves must fully engage in the
slots provided during suspension.
34 / 458
NOTICE
Material damage due to deformation of the
display shelves.
▪ Align the brackets in parallel.
▪ Align the display shelves horizontally.
Number and position of display shelves
Number of shelves see →Technical data
Appliance models with different display shelving
– AC-S
– AC-W
The bottom display shelf must be at the lowest posi-
tion.
Possible attachment positions for bottom display shelf:
Openings 1 to 7
2
Fig. 5: Bottom display shelf (1) on AC-S (2) and AC-W (3)
– Attach the brackets for the display shelves to the
openings of the attachment rails.
Fig. 6: Attach bracket (1) to openings (2)
– Attach the display shelves to the brackets.
1
Fig. 7: Attach display shelf (1) to bracket (2)
8.1
Electrical connection
The connection to the power supply is made by the
operator.
See →Start-up
For technical data see →Technical data
AHT Cooling Systems GmbH | en
1
3
2
1
2
409654_1_0120