1. INTRODUCTION

PowerCompact3020 is a leading device equipped with a wide range of functions for measuring and
monitoring power consumption and for advanced power and power quality analysis. This device can
measure, display, process and transmit all the parameters of an electrical system.
PowerCompact3020 is a measuring tool designed for those in need of an accurate and easy-to-use product.
It is aimed at both users who want to understand their systems better, and Energy Managers, system
installers, electricians, and maintenance workers, for diagnosis and intervention, or for the provision of
integral consulting services on electrical power.
PowerCompact3020 allows users to:
monitor loads, consumption and related costs;
check if the new systems are dimensioned correctly;
prevent overheating and lack of insulation due to high harmonics content;
solve any power factor correction problems;
identify and eliminate load peaks and excess demand, thereby reducing contractual power consumption;
monitor power and consumption in the different time bands;
check and assess the performance of UPSs, with AC/DC measurements;
measure signals - including asymmetrical signals - for PWM controls on inverters;
identify the cause of problems resulting from low quality power (presence of harmonics, interruptions,
overloads, dips, unbalance in voltage phases, etc.), which may bring about a production standstill, and
which may affect or reduce the life cycle of equipment and systems;
identify fast fluctuations and variations in current and voltage signals;
measure inrush current of electrical engines and equipment

2 . SAFETY

PowerCompact3020 has been designed and tested in accordance with the latest directives in force, and
complies with all technical and safety requirements.To preserve the product and ensure its safe operation,
follow the instructions and the CE markings contained herein.
CAUTION! Please read these instruction carefully before using the device.

2.1. Operator's safety

The instrument described herein must only be used by trained personnel.
Connection and maintenance operations must only be carried out by qualified and authorised
personnel, as they may result in electrocution, burns or explosions.
For the correct and safe use of the instrument, as well as for all installation and maintenance purposes,
operators must always comply with standard safety procedures. The manufacturer shall in no way be
liable if such procedures are not complied with.
Before connecting the instrument to the electrical system, as well as before handling, maintaining or
repairing the instrument, the instrument and the electrical cabinet to which it is connected must be
disconnected from any voltage source.
Before turning on the instrument, make sure the maximum voltage at the voltmeter inputs is 1000VAC
phase/phase or 600VAC phase/neutral.
If the instrument can no longer be operated safely, it must be discarded and measures must be taken to
prevent accidental use. Safe operation is no longer possible in the following cases:
if damage to instrument is clearly visible;