28
Attaching Disconnect Handle
®
NOTE: See idrive
main installation and
Tools Needed:
owners manual for idrive
®
parts.
UPPER POSITION
Phillips head
screwdriver
NOTE: Bring motor to the down position
#6-20 X 1/2"
by pulling the disconnect cable, insure
Wire cutters
SCREW
opener disconnect teeth are engaged
before installing disconnect handle.
Start the #6-20 x 1/2" screw into the
disconnect handle. Thread the
disconnect cable through the top of the
disconnect handle bracket and then the
HANDLE
disconnect handle.
Locate the disconnect handle in full
upper position of disconnect handle
bracket.
Remove all disconnect cable slack
DISCONNECT
EMERGENCY DISCONNECT
CABLE
between the opener and the top of the
LABEL
disconnect handle bracket. Tighten
#6-20 x 1/2" screw into the disconnect
handle until snug, and then tighten
screw an additional 1 to 1-1/2 turns to
DISCONNECT
secure disconnect cable to the
HANDLE
disconnect handle. Trim off excess cable
BRACKET
from bottom of the disconnect handle.
MANUAL OPERATED POSITION
MOTOR OPERATED POSITION
CAUTION: PULL CABLE ONLY TAUT
ENOUGH TO REMOVE THE CABLE SLACK.
PULLING THE CABLE MORE COULD
CAUSE OPENER TO DISCONNECT FROM
®
THE TORQUEMASTER
SPRING TUBE.
Apply emergency disconnect label next
to the mounted bracket. Use
mechanical fasteners if adhesive will
not adhere.
Using the emergency disconnect, pull
disconnect handle downwards and
place it in the manual door operated
position (Use disconnect label for
reference). Motor will be rotated 90°
from its packaged position.
If motor does not pivot 90°, see
troubleshooting section in the main
installation and owners manual of your
®
idrive
opener
27
Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer. To find your local Wayne-Dalton dealer, refer to your
local yellow pages/business listings or go to the Find a Dealer section online at www.wayne-dalton.com