6.3.4. "Failsafe mode"

Description
The controller enters failsafe mode when a
critical fault occurs (e.g. failure of the
UV-lamp).
If desired, the user can also select failsafe
mode manually from the menu.
In failsafe mode, the system runs like in the
run-in period. This means that grey water runs
through the tanks B1 and B2, before then
leaving the system via the overflow of tank B2.
Water in the storage tank B3 is provided via
the rainwater / drinking water feed
VA4.1/VA4.2.
In contrast to the run-in period, failsafe mode is
not exited automatically but remains in force
until the user expressly selects another mode
of operation from the menu. Failsafe mode is
also restored after a power failure.
Setting
Select mode of operation (see chapter 6.3)
Select
Acknowledge
Return to main page