P03 operation
• P030 durat. run-in
o Run-in duration (in days)
• P031 batch time
o Time of one treatment
• P032 sedim. period
o Resting time for the sediments to
settle
• P033 fallback time
o Time until switchover to "automatic"
(e.g. after manual operation)
• P034 start time
o Time of the first provision of process
water on the day (time hh:mm)
(Attention: 00:00 = start time function
deactivated)
• P035 max. off-time
o Time after the system returns to the
"run-in period" after a power failure
P04 aeration
• P040 V1 off
o Interval, aeration time tank B1 off
• P041 V1 on
o Interval, aeration time tank B1 on
• P042 V2 off
o Interval, aeration time tank B2 off
• P043 V2 on
o Interval, aeration time tank B2 on
P05 tank B1
• P0500 L01 sens.max
o Maximum pressure range of the
installed sensor
• P0501 L01 sens.min
o Minimum pressure range of the
installed sensor
• P0502 L01 100%
o Water level height at 100% (overflow)
• P0503 L01 max ON
o Max. fill level height (< water level
100%)
• P0504 L01 max OFF
o Max. fill level not reached (< Max ON)
• P0505 L01 RI ON
o Intermediate level in run-in period, at
which the submersible pump 1 is
switched on after P0506
• P0506 L01 RI OFF
o Intermediate level in run-in period, at
which the submersible pump 1 is
switched off
EN 36
Operating Manual AquaCycle 2500
• P0507 L01 P1 ON
o Switch-on level of the submersible
pump P1 (P0507>P0508)
• P0508 L01 P1 OFF
o Switch-off level of the submersible
pump P1 (P0507>P0508)
• P0509 L01 V1 ON
o Switch-on level of the aeration V1
(P0509>P0510)
• P0510 L01 V1 OFF
o Switch-off level of the aeration V1
(P0509>P0510)
P06 tank B2
• P0600 L02 sens.max
o Maximum pressure range of the
installed sensor
• P0601 L02 sens.min
o Minimum pressure range of the
installed sensor
• P0602 L02 100%
o Water level height at 100% (overflow)
• P0603 L02 max ON
o Max. fill level height (< water level
100%) (P1 goes off)
• P0604 L02 max OFF
o Max. fill level not reached
(< Max ON)
• P0605 L02 P2 ON
o Switch-on level of the submersible
pump P2 (P0507>P0508)
• P0606 L02 P2 OFF
o Switch-off level of the submersible
pump P2 (P0607>P0608)
• P0607 L02 V2 ON
o Switch-on level of the aeration V2
(P0609>P0610)
• P0608 L02 V2 OFF
o Switch-off level of the aeration V2
(P0609>P0610)
Version 2.5