6.7.1. Manual operation
(function check)
Attention:
When you change to this
operating mode, all actuators (apart from
enabling of the pressure booster system) are
initially deactivated.
Note!
Manual operation is intended for
performing a manual function
check of the individual actuators
and is not for operating the
system.
If the user performs no action within a defined
fallback time, the system automatically
changes to the previously active mode of
operation and exits the "manual operation"
mask.
Select "service" (see chapter 6.7)
Acknowledge
Select component
1= in operation; 0= not in
operation
Acknowledge
Return to main page
Version 2.5
Operating Manual AquaCycle 2500
Components that can be operated (for
positions, see chapter 4.2)
-
lamp UV
-
pump P1
-
pump P2
-
aeration V1
-
aeration V2
-
ball valve VA1.1
-
ball valve VA1.1
-
ball valve VA1.3
-
solenoid valve VA3
-
solenoid valve VA4.1
-
solenoid valve VA4.2
-
solenoid valve VA4.3
-
LED green
-
LED red
Note!
When operating the pump
P2, the UV lamp must be
switched on manually in
order to hygienise the water
during pumping from the
tank B2 to B3. The water
quality will be impaired if
this is not observed.