7. USER INSTRUCTIONS
7.1. CONTROL PANEL
Description of control panel
ON /OFF
On/off pannel control
START/STOP
This button is also used to start/interrupt operation
during the blast chill/shock freeze/conservation cycle
+3°C SOFT BLAST CHILL
Selection cycle blast chill +3 soft
HARD BLAST CHILL +3°C
Selection cycle chill +3 hard
–18°C SOFT SHOCK FREEZE
Selection cycle shock freeze -18 soft
HARD SHOCK FREEZE -18°C
Selection cycle freeze -18 hard
DEFROST
Start/stop defrost. By pressing the button for extended time,
the temperature of the evaporator probe is displayed
PROBE HEATING
Heating for extraction of food probe
MULTI-POINT/MULTIPROBE PIN PROBE
Visualizes the temperature of the needle probe
Extended pressing displays the 4 temperatures
STERILISATION
Start/stop sterilisation process
PROGRAMME
Memory or recalls a blast chill/shock freeze cycle on memory
HACCP
Enter/exit HACCP menu
DIAL
value selected; during blast chilling/shock
freezing displays for a few seconds the time
elapsed from start of cycle (by turning the dial)
increases, decreases and confi rms the
Description of the display and symbols
DISPLAY 1
DISPLAY 2
DISPLAY 1
Displays pin probe temperature or time
DISPLAY 2
Displays temperature of the cabinet
DISPLAY 3
Displays the operational phase in progress (1-3)
Number of pin probe inserted in core
Cabinet temperature
Heating active pin probe
Blast chill/shock freeze cycle with pin probe
(fl ashing in pin probe insertion test)
Multipoint probe automatic freez./chill. cycle
(fl ashing during pin insertion test)
Blast chill/shock freeze cycle with timer
Sterilisation in progress
Blast chill cycle function selected (+3ºC)
Shock freeze cycle function selected (-18ºC)
Hard phase selected
Blast chill in progress
(fl ashing active compressor delay)
Conservation phase in progress
Machine in Stop mode
HACCP alarm
HACCP
HACCP
21 - GB
DISPLAY 3