22. INITIALIZATION OF THE SETTING DATA

1
1. When you carry out the aforementioned operation, the neutral position correction value for the
pedal sensor is also initialized. It is therefore necessary to carry out automatic correction of the
pedal sensor neutral position before using the sewing machine.
(Refer "20. AUTOMATIC COMPENSATION OF NEUTRAL POINT OF THE PEDAL SENSOR" p.18.)
2. When you carry out the aforementioned operation, the machine-head adjustment values are also
initialized. It is therefore necessary to carry out adjustment of the machine head before using the
sewing machine.
(Refer "5. ADJUSTING THE MACHINE HEAD" p.3.)
3. Even when this operation is performed, the sewing data set by the operation panel cannot be
initialized.

23. CHECKING PROCEDURE OF THE ERROR CODE

1
2
2
3
All contents of function setting can be returned to the
standard set values.
1) Pressing all switches 1 , 2 and 3 , turn ON the
power switch.
2) "
" is displayed on indicator with a "blip" to
start initialization.
3) The buzzer sounds after approximately one
second (single sound three times, "blip", "blip",
and "blip"), and the setting data returns to the
standard setting value.
Do not turn OFF the power on the way of
initializing operation. Program of the main
unit may be broken.
4) Turn OFF the power switch and turn ON the
power switch again to return to the normal mode.
1) Turn ON the power switch with switch 1 held
pressed.
2) The latest error number is displayed on indicator
with blip.
3) Contents of previous errors can be checked by
pressing switch 2 .
(When the procedure has reached the end, two alarm
sounds in single tone will be heard, "blip" "blip".)