Percent Mode

3.4
Use this application to measure the weight of a sample displayed as a percentage of a pre-established
reference weight.

3.4.1 Enter the Mode

To enter the percent mode from any application mode:
Press and hold the Mode button until
1.
When the Mode button is released, the display shows
2.
3.
If you need to clear the stored reference weight of the last time, press the Yes button. Then go to step 5.
Note: If captured weight is more than or equal to 1d or is less than or equal to -1d, the display will show
CLr.PAN
until the sample is removed from the pan.
If you need to recall the stored reference weight of the last time and continue to use it, press the No button
4.
and start percent weighing.
Note: If no reference weight has been previously stored, step 3 and 4 will be omitted.
5.
The display shows the

3.4.2 Establish a Reference Weight

To establish a reference weight:
Follow the previous step 5. When you see
samples on the pan and press the Yes button to capture the current stable weight.
Note:
You can press the【】
For i-DT61PW model, during the capture process, the display shows
If the reference weight is less than 100d during the capture process, the display will show
seconds and then return to showing
button to re-establish a reference weight.

3.4.3 Start Percent Weighing

1.
Place a sample on the pan and read the percent. The current percent value and % icon are displayed.
2.
Press the Function button to temporarily display the reference weight.
seconds. Then the reference weight value is displayed for 1.5 seconds in the current unit of measurement.
Note: Please refer to Check in the Weighing Mode section for how to use Check in the Percent Weighing
mode.

3.4.4 Application Settings

The application can be customized for user preferences. Please refer to Application Settings section in
Weighing Mode for details about how to enter application settings.
The Percent Weighing Configurations are defined below (defaults in Bold).
Item
PerCNt
Percent (
Note: you cannot disable Percent if you are in the mode currently.
PErCNt
PUt.rEF
and the % icon.
PUt.rEF
button to tare. The center of zero, PT or NET icons will light as appropriate.
PUt.rEF
. Please replace the samples on the pan and press the Yes
Available Settings
On, Off
is displayed.
CLr.rEF
and the % icon.
displayed on the screen, place the specified quantity of
- - - - -
Comments
To enable Percent Weighing
Defender 6000 Indicators
.
rEF.Err
rEF.wWt
is displayed for 0.5
for 1.5

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido