Instructions for assembly

Start of operation

Once the hob has been installed and the power supply has been
provided (mains connected) an automatic test of the controls will
be carried out and information for Customer Service will be indi-
cated.
This indication will go off after 30 seconds or as soon as a key
has been pressed.
Briefly wipe over the surface of the hob with a sponge and soapy
water and then dry with a clean cloth.

Technical data

Dimensions
Hob (Fac)
Height/ Width/ Depth
Installation dimensions
Width/ Depth
Cooking zones
Back left
Ø cm / kW
Front left
Ø cm / kW
Front right
Ø cm / kW
Back right
Ø cm / kW

Electrical connection

Mains voltage
Component rated voltage
Hob, total
Dimensions
Hob (Fac)
Height/ Width/ Depth
Installation dimensions
Width/ Depth
Cooking zones
Back left
Ø cm / kW
Front left
Ø cm / kW
Front right
Ø cm / kW
Back right
Ø cm / kW
Electrical connection
Mains voltage
Component rated voltage
Hob, total
Dimensions
Hob (Fac)
Height/ Width/ Depth
Installation dimensions
Width/ Depth
Cooking zones
Back left
Ø cm / kW
Front left
Ø cm / kW
Right
Ø cm / kW
Electrical connection
Mains voltage
Component rated voltage
Hob, total
This appliance is intended to operate from a power supply network
with a maximum Zmax system impedance of 0.389 + j0.243 ohms
(service line) at the transfer point.
Users are to ensure that the appliance is only operated from a
power supply network that fulfils this requirement. Details on the
system impedance can be obtained from your local electricity
supplier if necessary.
The Zmax system impedance at the transfer point (service line) is
generally below 0.2 ohms.
mm
50 x 600 x 520
mm
560 x 490
18/max. 2.8
18/max. 2.8
16/max. 2.0
21/max. 3.1
400-415V 2N~, 50-60 Hz
230 - 240V
kW
5.9
mm
50 x 800 x 520
mm
750 x 490
18/max. 2.8
18/max. 2.8
16/max. 2.0
21/max. 3.1
400-415V 2N~, 50-60 Hz
230 - 240V
kW
5.9
mm
50 x 600 x 520
mm
560 x 490
16/max. 2.0
21/max. 3.1
29/max. 2.8
400-415V 2N~, 50-60 Hz
230 - 240V
kW
5.9
Electrical connection
• The electrical connection must be carried out by a quali-
fied electrician who is authorised to carry out such work!
• Statutory regulations and the connection specifications issued
by the local power supply company must be strictly observed.
• When connecting the appliance it must be ensured that there
is a device which makes it possible to disconnect it from the
mains at all poles with a contact opening width of at least
3 mm. Line-protecting switches, fuses or contactors are suita-
ble cut-out devices.
• When connecting and repairing the appliance disconnect it
from the electricity supply with one of these devices.
• Full protection against accidental contact must be ensured on
installation.
• The earth wire must be sufficiently long so that if the strain
relief fails, the live wires of the connecting cable are subjected
to tension before the earth wire.
• Any superfluous cable must be removed from the installation
area beneath the appliance.
• The induction hob has been fitted with a temperature-resistant
connection cable in the factory.
• Connection to the mains is carried out in accordance with the
circuit diagram, unless the connection cable is already fitted
with a plug.
• If damaged, the manufacturer or his Customer Service must
replace the connection cable installed with a special connec-
tion cable.
Attention!
Incorrect connection may result in the power electronics unit
being destroyed.
Electrical connections
* Attention! Special power supply 230 - 240 V 3~ !