CEBORA S.p.A.
5.1 Err 51: Torch type unknown
Correct torch inserted.
Check the connection to connector J6 of the
control board (48);
Make sure that the torch inserted in the torch
central adapter (61) is intact;
Make sure that the torch central adapter (61) is
intact;
replace the control board (48);
5.2 Err 55: Worn out electrode
Replaced electrode
Check the connection to connector J6 of the
control board (48);
Make sure that the torch inserted in the torch
central adapter (61) is intact;
Make sure that the torch central adapter (61) is
intact;
replace the control board (48);
5.3 Err 73: Output diodes overtemperature
Machine just powered up after an idle period with cold dissipaters (< = 30 °C).
Check the connection to connector J5 of the
control board (48);
Make sure that the sensor connection wire is
intact;
Make sure that the resistor value of the sensor is
approximately 4700 Ohm at 20°C
replace the control board (48);
5.4 Err 74: IGBT inverter overtemperature
Machine just powered up after an idle period with cold dissipaters (< = 30 °C).
3302336-B
YES
Correct?
Insert the torch as shown in the machine's
Instruction Manual.
YES
Correct?
Replace the connection that connects the J4
connector on the diode board (32) to the J11
connector on the control board (48).
Replace the diode board (32) and the control
board (48).
YES
Correct?
Wait until the IGBT dissipater (39) cools
down.
NO
NO
NO
59
20/12/2019