CEBORA S.p.A.
Connector table
Connector Terminals
CN1
1 - 2
CN2
1 - 3
mains.
CN2
1 - 4
mains.
-
P1 - P2
-
P3 - P4
3302336-B
Function
to ends of snubber resistor (45)
relay RL2 command input for connection of primary coils for 400 VAC
relay RL1 command input for connection of primary coils for 230 VAC
connection to primary coil of transformer (52).
connection to primary coil of transformer (52).
69
20/12/2019