5.7 Err 67: Mains voltage does not meet specifications

Mains voltage values during machine operation intervals
Make sure that all three phases are connected
to the machine by reading the voltage directly
upstream and downstream from the switch (10);
replace the switch (10);
replace the plug and/or cable, if worn;
Make sure that the neutral terminal has not
accidentally been connected in place of a
phase;
repeat the tests described in paragraph 3.3.1
Replace the services board (6);

5.8 Err 53: START closed at machine start-up or power source reset

See par. 4.3

5.9 Err Vin 1

For 3 consecutive ms a voltage lower than 16.0V is read at the output of bridge
D23 of the control board (48).
See par. 4.1 MAINS SUITABILITY TEST 1.

5.10 Err Vin 2

For 3 consecutive ms a voltage lower than 12.0V is read by regulator U11 of the
control board (48).
See par. 4.1 MAINS SUITABILITY TEST 1.
3302336-B
YES
Correct?
Check the switchboard and make sure that
all fuses, thermal cutout switches and
differential switches are intact;
Check the in-house mains;