6.3 Inserting the SIM card

T
ATTENTION
Damage to components
Damage to components or the charging station from elec-
trostatic discharging.
f Touch an earthed metal part before inserting the
SIM card.
f Insert SIM card in the micro SIM slot (2) of the ECU on
the left-hand side (AF1).
Î "Fig. 20: Connections for the configuration on the ECU"

6.4 Switching on the device

T
DANGER
Electric shock hazard when devices are damaged
If a damaged device is used people can be seriously
injured or killed through an electric shock.
f Do not use the device if it is damaged.
f Mark the damaged device to ensure that no one con-
tinues using it.
f Eliminate damage immediately.
f If necessary take the device out of service.
Requirements:
„ Device is installed correctly.
„ Device is in a proper condition.
„ All protective devices (e.g. residual current circuit
breakers, line circuit breakers and contactors) function
correctly and are switched on.
„ During the initial setting-up process, the device was
inspected in accordance with IEC 60364-6 and the
applicable national regulations (e.g. in Germany: DIN
VDE 0100-600).
f Switch on the power supply and check.
Î "6.5 Monitoring the power supply"
9
LED "Standby" is illuminated on the LED information
panel.
34

6.5 Monitoring the power supply

The device is monitored by a phase sequence relay.
It checks the three phases (L1, L2, L3) and the neutral
conductor (N) of the power supply for correct phase
sequence, phase failure or undervoltage.
Operating status display:
Three phases, clockwise field of rotation:
L3 X
L2 X
f Use terminals L1, L2, L3, N, PE.
L1 X
f Set relay potentiometer to 3.
SOR74
1
3
9
The green LED is lit.
N X
9
The device is ready for use.
X 16
15 18
Three phases, anti-clockwise field of rotation:
L3 X
L2 X
f Use terminals L1, L2, L3, N, PE.
L1 X
f Set relay potentiometer to 3.
SOR74
1
3
9
The green LED is flashing.
N X
9
The device is not ready for use. A clock-
X 16
15 18
wise field of rotation is required.
One phase:
L3 X
L2 X
f Use terminals L1, N, PE.
L1 X
f Set relay potentiometer to 1.
SOR74
1
3
9
The green LED is lit.
N X
9
The device is ready for use.
X 16
15 18
The evaluation of the relay potentiometer occurs only
once, after applying the supply voltage.