4.1.2 ROW SHUT-OFF (TRAMLINE)

The MAIN screen shows the conditions of the row shut-off (2, Fig. 7):

4.1.3 FAN DRIVE SPEED

The fan drive speed is controlled from the monitor; the following alarms are available (for configuration see chap. 4.4.9.):
Fan drive low speed alarm
Fan drive high speed alarm
4.1.4 MANUAL ADVANCEMENT OF TRAMLINE "PASSAGE NUMBER"
Press the
key to modify current passage number manually.
Passages are detected automatically from the switch (finger), every time the seed drill lowers or lifts.
4.1.5 BLOCKING THE TRAMLINE "PASSAGE NUMBER" COUNT
Press the
function key to block the automatic count of the tramline passages (e.g.: lower and lift the equipment to overcome
an obstacle along the passage).
The
icon is displayed (blocked count).
To restore the count, press the

4.2 RATE Menu

The RATE screen (Fig. 11) allows setting the amount of product to be distributed.
When working, this screen allows modifying the amount of product to be distributed per hectare (Kg/Ha or Seeds/m²).
Note: The measure unit must be set in the CONFIGURATION menu.
The parameters displayed in the RATE screen are:
1) Current dosing display
2) Set dosing display
3) Percentage difference between current dosing and that set;
4) Set step to vary the dosing amount
5) Manual variation of the dosing with set step (the value is set in the
CONFIGURATION
CUSTOMISE
menu) using the function keys (E and F, Fig. 1) in
correspondence with + and -.
6) "Reset": reset the current dosing instead of that programmed.
7) Maximum work speed where the current dosing can be kept
8) manual setting of the dosing
9) Numerical index of the menu displayed.
Code G19503490
USE AND MAINTENANCE
function key.
OPERATOR CONFIGURATION