8.2 FACTORY CONFIGURATION

CONFIGURATION
This screen allows setting the factory settings described below (Fig. 72).
To modify the parameters:
1)
set the parameter required using arrows
2)
Press OK to modify the parameter;
3)
Use arrows
4)
Press OK to save the parameter or ESC to cancel the operation;
8.2.1 INSTRUMENT
CONFIGURATION
This screen allows setting the following parameters (Fig. 73):
"Fan": is the calibration factor of the fan drive, indicated as PPR. If the value is set as
0.0, both the fan drive alarms and its speed indication are disabled.
TL Advancement: is the number of seconds where the tramline advancement sensor
must be closed before the system increases the counter;
TL Debouncing: is the number of seconds where the tramline advancement sensor
must be open before the system accepts a different status;
Level 1: enables or disables sensor 1
Level 2: enables or disables sensor 2
Calibration: two different modes can be set
"Auto": the monitor automatically activates the linear actuator to open the
seeding door when the seeding test button is activated;
"Man": the monitor does not manage the seeding door;
Calibration time: is the number of seconds (during the seeding test phase) over which
the monitor triggers the open seeding test door alarm

8.2.2 MODULO MOTORE [MOTOR MODULE]

CONFIGURATION
This screen allows setting the following parameters (Fig. 73):
"Gear box Ratio": is the gearbox reduction ratio
"PPR Encoder": is the number of impulses of the motor encoder per every seed motor
shaft rotation
"Max Current": maximum current that can be provided by the motor module before the
relative alarm is triggered
"Max Speed": maximum speed of the seeding motor; it is used to calculate the
maximum seeding speed and relative alarm triggered when the maximum seeding
speed is exceeded;
"Max Temp": maximum temperature of the motor module before activating the relative
alarm;
"PPR shaft": number of impulses per rev deriving from the seeding shaft sensor.
When this value is set to zero, the relative alarm is deactivated.
Code G19503490
USE AND MAINTENANCE
FACTORY
CONFIGURATION
and
to modify the parameters
FACTORY
CONFIGURATION
FACTORY
CONFIGURATION
;
INSTRUMENT
MOTOR MODULE
Fig. 72
Fig. 73
Fig. 74
EN
- 34