8 DESCRIPTION OF PROTECTED MENUS
8.1 SEED DRILL CONFIGURATION
CONFIGURATION
The "seed drill configuration" allows setting the presence of some contents relative to Genius
Lite system.
8.1.1 C/O & TL + SELECT
CONFIGURATION
This screen allows selecting the "component" that will provide to the system the advancement
indication of the tramline value.
Selecting
the left image using the arrows : a sensor indicates the status of the tool
(working or not); whilst, the tramline count is provided by another switch, called finger.
Selecting
the right image using the arrows : the finger switch indicates the tramline
count advancement.
In both cases, press OK (E, Fig. 1) to save or ESC to cancel the operation.
The base parameter set is the one on the right, which is the selection that must be used.
8.1.2 PRODUCT CALIBRATION BUTTON
CONFIGURATION
This screen allows selecting the "component" that will provide to the system the seeding test
indication.
Selecting
the left image using the arrows : indicates the presence of a bistable switch;
the first activation indicates the seeding motor advancement; the second activation indicates
the seeding motor stop.
Selected by the arrows
switch; the seeding motor is activated by keeping this button pressed; when it is released, the
seeding motor stops.
In both cases, press OK (E, Fig. 1) to save or ESC to cancel the operation.
The base parameter set is the one on the right, which is the selection that must be used
Code G19503490
USE AND MAINTENANCE
SEED DRILL CONFIGURATION
SEED DRILL
CONFIGURATION
SEED
DRILL
CONFIGURATION
, the image on the right indicates the presence of a monostable
C/O & TL + SELECT
PULS.
CALIBRAZIONE
[CALIBRATION
BUTTON]
Fig. 66
Fig. 67
Fig. 68
EN
- 32