4.4.9 ALARM SETTING
CONFIGURATION
Alarm setting (8, Fig. 15): Menu for setting alarms for the fan drive rotation and hopper level
(Fig. 15 and Fig. 52).
Parameters to be entered:
Fan drive rotation minimum threshold alarm (see Table 4);
fan drive rotation maximum threshold alarm (see Table 4);
hopper level alarm: ON / OFF
To modify the parameters:
1)
set the parameter required using arrows
2)
Press OK to modify the parameter;
3)
Use arrows
4)
Press OK to save the parameter or ESC to cancel the operation;
Normal seeds
Small seeds
Fertiliser (up to 200 Kg/ha)
Fertiliser (over 200 Kg/ha)
4.5 PRODUCT CALIBRATION
The aim of the test is to calculate the amount of product distributed for each rotation of the dosing roller.
-
Inspect the area around the machine before start running the equipment. Ensure that no persons are present,
especially children or pets and that visibility is good.
-
Before performing the dosing test, ensure that no foreign bodies are present inside the hopper and dosers.
Code G19503490
USE AND MAINTENANCE
ALARM SETTING
and
to modify the parameters
Product
Table 4
Verify the use of the suitable dosing roller.
;
Fan drive speed [rpm]
Min.
Max.
3700
3900
2500
3000
3500
3700
3700
3900
ATTENTION
Moving components!
IMPORTANT
Fig. 15
Fig. 52
EN
- 23