ELECTRICAL CONNECTIONS: FASTON
1
CF1 - CF3
2
CF2 - CF4
3
CF5 - CF6
4
CF7 - CF8
5
CF9 - CF10
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Morsetto
Posizione
1
2
JP1
3
4
5
6
7
8
JP2
9
10
11
12
13
14
15
16
JP5
17
18
19
20
21
22
JP4
23
24
Primary connection of 230Vac transformer (black cables)
Secondary connection of 14Vac transformer (red cables)
Secondary connection of 22Vac transformer (blue cables)
Motor 2 capacitor connection
Motor 1 capacitor connection
Segnale
Descrizione
PHASE
Power supply 230Vac
NEUTR
Power supply 230Vac
Ground wire connection
GND
Ground wire connection
GND
Flashing light output 230Vac 40W
LAMP
Flashing light output 230 Vac 40W
LAMP
Motor 1 connection 1 (opening)
OPEN
COM
Common motor 1
Motor 1 connection 1 (closing)
CLOSE
Motor 2 connection (opening)
OPEN
COM
Common motor 2
Motor 2 connection (closing)
CLOSE
Negative electrical lock
COM
EL1
Positive +12 Vdc motor 1 electrical lock
EL2
Positive +12 Vdc motor 2 electrical lock
Negative external accessories power supply
GND
Warning light output +24 Vdc 3W max
SPIA
External accessories (photocells, radio...) +24Vdc power supply
+ ACC
External safety devices +24Vdc power supply.
+ SAF
CAUTION: output present only during the operating cycle
START (N.O.) input
START
PEDESTRIAN input (N.O.) (It opens for the time set in menu H10).
WARNING
PED
After an emergency intervention with motion intervention of the second leaf, the
pedestrian command will start both motors.
STOP input (N.C.).
STOP
If not used, jump with terminal n° 32
Limit switch input opens motor 1 (N.C.).
FCAM1
If not used, disable during the programming phase.
Limit switch input closes motor 1 (N.C.).
FCCM1
If not used, disable during the programming phase.
Operation:
Fast flashing during opening, off during pause,
slow flashing during closing
Operation:
Slow flashing during opening, fixed light during
pause, fast flashing during closing.