Descargar Imprimir esta página

GiBiDi BA230 Manual De Instrucciones página 33

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 66
BA230
A9
DEAD MAN LOGIC
MENU C: FUNCTIONS SELECTIONS
KEY + enters the following menu C1-C2-C3-...
KEY – enters the previous menu C3-C2-C1...
KEY ESC leaves the menu
KEY OK enables Y (yes). It enables or selects the function
KEY OK enables N (no). It disables the function
Menu
Function
C1
AUTOMATIC CLOSING
C2
FAST CLOSING
C3
PRE-FLASHING
SAFETY DEVICES TEST
C4
See also menu C20
The opening and closing movement in the dead man's mode stops
always on the first limit switch.
The possible regulations are: PHASE SHIFT IN OPENING - PHASE
Y
SHIFT IN CLOSING.
The enabling of this menu automatically disables A6-A7-A8.
Status
Description
Enables automatic closing after both complete opening and pedestrian
YT
opening.
Enables only automatic closing after a complete opening.
If pedestrian opening is enabled, the pedestrian key will close the gate.
YS
YP
Enables only automatic closing after a pedestrian opening.
Disables automatic closing
If the pedestrian opening is enabled, the pedestrian key will close the
gate.
N
If complete opening is enabled, a Start command will close the gate and
the pedestrian key will be uninfluemtial.
Enables fast closing function
Operation:
Y
Enabled only on photocell 1.
Reduces pause time to 3 s following interception and subsequent
freeing of the photocells.
N
Disables fast closing function
Enables 3-second pre-flashing before motors start
Y
Disables pre-flashing. The flashing light and the motors start at the
N
same time.
Enables the safety devices test
When the device is enabled (edge intercepted), the writing SAF
appears on the LCD
Operation:
PHASE 1: when the Start or the Pedestrian command is given, the
electronic circuit is tested: relay, triac, etc.
If an anomaly is detected, it will be indicated by 4 long flashes (2 sec.) of
the flashing light. The test must be performed when the motors are
Y
connected.
If the control unit is set for one motor, the test will be performed only for
motor 1 circuit.
WARNING: During the test, the motors will be activated in opening and
closing for about 300 msec.
DUE TO THE MOTION, THE DOOR MAY CRASH AGAINST THE
MECHANICAL STOPS. CHECK THE SYSTEM SAFETY/INTEGRITY
AFTER THIS PHASE.
33
UK

Publicidad

loading

Este manual también es adecuado para:

As05550