Descargar Imprimir esta página

GiBiDi BA230 Manual De Instrucciones página 26

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 66
26
UK
25
26
27
28
JP4
29
30
31
32
33
JP6
34
JP7
PROTECTION FUSES
Position
Value
F1
6 A
F2
315 mA
Limit switch input opens motor 2 (N.C.).
FCAM2
If not used, disable during the programming phase.
Limit switch input closes motor 2 (N.C.).
FCCM2
If not used, disable during the programming phase.
PHOTOCELL 2 input (N.C.).
If not used, disable during the programming phase.
Operation:
Input enabled during both opening and closing.
If intercepted, it stops the motion immediately and holds it stopped until the photocell is
PH2
freed. Upon release, motion always starts in opening.
If intercepted when the gate is closed, following a Start command it does not allow the
opening of the gate: this will be signalled with 5 fast flashes, then the warning light turns
on to indicate that the door is not in stand-by. Upon release, the gate will start opening
without further commands.
If intercepted during pause, it reloads the pause time.
Multitasking input
RISERVA
SAFETY DEVICES input (see menu C9)
If not used, disable during the programming phase.
Operation:
Input enabled during both opening and closing.
It stops and inverts the motion for 2 s. The gate will remain locked until the next Start
pulse, which will make it start in the obstacle-freeing direction.
COSTA
If the input is enabled when the door is in stand-by, after a Start or a Pedestrian command
the door will not move and 3 long flashes (2 sec.) will signal the fault.
If the input is enabled when the door is in pause, the door does not close automatically (if
automatic closing is enabled) and 3 long flashes (2 sec.) will signal the fault.
THE EDGE ENABLING IS SIGNALLED BY THE WRITING "SAF" ON THE LCD.
Not used
PHOTOCELL 1 input (N.C.).
If not used, disable during the programming phase.
Operation:
PH1
Input enabled only during closing. It stops and inverts the motion, opening the gate
completely. If the gate is closed, it does not affect its functioning.
If intercepted during pause, it reloads pause time (if C2 disabled).
It can be enabled to manage FAST CLOSING.
COM
COMMON INPUTS - OUTPUTS
ANTENNA BRAID input
GND
ANTENNA SIGNAL input
ANT
Connector for plug-in radio receiver
Type
Description
FAST
Motors and primary transformer protection
FAST
Low tension and accessories protection
External watch:
SEE PROGRAMMING C16-C17-C18
BA230

Publicidad

loading

Este manual también es adecuado para:

As05550