UK
Photo 1 test failed at opening
Photo 1 test failed at closing
TRIAC test failed at opening
TRIAC test failed at closing
Edge N.C. test failed at opening
Edge N.C. test failed at closing
Edge 8K2 test failed at opening
Edge 8K2 test failed at closing
Expired maintenance
(*) If the flashing light setting is with fixed light (C15 d), the blinking is not present but only the fixed
switching on.

DEFAULT SETTINGS

• Active parameters type A:
A2
Y
A5
Y
A8
Y
• Parameters type C:
C1
YT
C2
N
C3
Y
C4
N
C5
E1
C6
N
C7
N
C8
N
C9
NC
C11
N
C13
N
C14
N
Y
C15
C16
N
C17
N
N
C18
C19
N
C20
N
• Parameters type F:
F1
10
SWING GATE/OVERHEAD DOOR/BARRIER TYPE
2 MOTORS
AUTOMATIC-CONDOMINIUM USING
GENERAL AND PEDESTRIAN AUTOMATIC CLOSING ENABLED
FAST CLOSING DISABLED
PREFLASHING ENABLED
SAFETY DEVICES TEST DISABLED
LIMIT SWITCH ENABLED (single pair)
DECELERATIONS DISABLED
WATER HAMMER DISABLED
FINAL CLOSING STROKE DISABLED
SAFETY DEVICE (EDGE) WITH N.C. CONTACT
COURTESY LIGHT DISABLED
T3 EXCLUDED
IN PEDESTRIAN CLOSING, IT ENABLES COMPLETE OPENING
INTERMITTENT FLASHING LIGHT
EXTERNAL CLOCK CONTACT DISABLED
EXTERNAL CLOCK CONTACT DISABLED
EXTERNAL CLOCK CONTACT DISABLED
OLEODYNAMIC BLOCK MAINTENANCE DISABLED
PHOTO 1 TEST DISABLED
MOTOR 1 FORCE
4 fast flashings
4 fast flashings
4 slow flashings
4 slow flashings
3 slow flashings
3 slow flashings
2 slow flashings
2 slow flashings
1 minute slow flashing
with closed door
BA230
Blocked closed door
Blocked open door
Blocked closed door
Blocked open door
Blocked closed door
Blocked open door
Blocked closed door
Blocked open door
None