Descargar Imprimir esta página

GiBiDi BA230 Manual De Instrucciones página 35

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 66
BA230
FINAL STROKE IN OPENING
C8
AND CLOSING
C9
SAFETY DEVICE
C10
DISABLED
C11
COURTESY LIGHT
C13
T3 ADDITIONAL TIME
C14
INVERSION FROM PEDESTRIAN
C15
FLASHING LIGHT
EXTERNAL WATCH,
C16
CLOSING ALLOWED
If decelerations are enabled, the pulse is given at the end of the
deceleration time.
Y
The final stroke is not managed by the safety devices.
Disabled with sliding configuration and with dead man logic
Disables the closing final stroke function.
N
Enables the edge with 8K2 in series resistance.
Runs the safety test on the 8K2 edge (check the correct resistive value)
8K2
if enabled with menu C4 – E3.
Enables the edge provided with n.c. contact (normally closed).
NC
Runs the safety test on the n.c. edge if enabled with menu C4 - E3.
Enables the courtesy light working on motor 2 output .
If the installation has 2 motors the courtesy light will not be active
Y1
COURTESY LIGHT 230 Vac (see diagram).
Timed 3 min after the motors motion end.
Enables the courtesy light working on electrical lock 2 output
COURTESY LIGHT 12 Vdc.
Y2
Timed 3 min after the motors motion end.
Disables the courtesy light.
N
T3 excluded.
N
Sets T3 as the time set for the deceleration with the same setting of
YF
menus F1 and F5.
Sets T3 as the time set for the deceleration with the same setting of
YS
menus F2 and F6.
During the PEDESTRIAN closing, the PHOTO1-PHOTO2-
Y
PEDESTRIAN command will determine only the pedestrian opening.
The START will cause complete opening.
During the PEDESTRIAN closing,
N
PEDESTRIAN-START command will cause the complete opening.
Blinking flashing light output (slow blinking in opening, fast in closing).
Y
Flashing light fixed output.
N
Enables the RESERVE input for the connection of an external watch.
Operation:
If the contact on the RESERVE input is closed, following a START
command the door opens but does not close automatically. When the
Y
contact closes, after the pause time the door will close automatically.
When the door is open, closing can be started with a START command if
the menu enabled is STEP-BY-STEP or STEP-BY-STEP WITH STOP.
CAUTION: remember to set automatic closing.
Disables the RESERVE input.
N
UK
the PHOTO1-PHOTO2-
35

Publicidad

loading

Este manual también es adecuado para: