UK
EXTERNAL WATCH,
C17
CLOSING NOT ALLOWED
EXTERNAL WATCH
C18
AUTOMATIC OPENING
AND CLOSING COMMAND
OLEODYNAMIC
C19
BLOCK MAINTENANCE
C20
PHOTOCELL 1 TEST
C21
AUTOMATIC PROGRAMMING
MENU F: FORCE AND SPEED ADJUSTMENTS
Menu
Function
F1
MOTOR 1 FORCE
Enables the RESERVE input for the connection of an external watch
Operation:
If the contact on the RESERVE input is closed, following a START
Y
command the door opens but does not close automatically. When the
contact closes, after the pause time the door will close automatically.
Closing cannot be started with a START command.
CAUTION: remember to set automatic closing.
N
Disables the RESERVE input.
Enables the RESERVE input for the connection of an external watch
Operation:
When the contact on the RESERVE input is closet, an automatic
opening command will be enabled (a START command is not required).
The door will open but will not close automatically. When the contact is
closed, tthe door will close automatically after the pause time.
Y
Closing cannot be enabled with START.
CAUTION: remember to set automatic closing.
Disabilita I'ingresso RISERVA.
N
Enables the oleodynamic block maintenance function ONLY FOR
OLEODYNAMIC OPERATORS
Operation:
If in the last 5 hours the gate has not performed a manoeuvre, a 2 s
pulse in closing is given.
Y
The enabling of the STOP key in any moment disables the function.
The function is automatically disabled with SLIDING - DEAD MAN
configuration
Disables the oleodynamic block maintenance
N
Enables photocell 1 test.
The photocell 1 transmitter must be connected to the clamps 16 and 19.
Operation:
When the "Start" or the "Pedestrian" command is given, the power to
Y
safety devices is cut off for 0,5 and then restored: if the photocell 1 input
opens and immediately returns NC the motors start, otherwise a fault will
be signalled by 4 blinks (1 sec.) of the flashing light.
Disables photocell 1 test 1.
N
Enables times programming in self-learning.
Operation:
Y
See "Times self-learning procedure".
Description
Adjusts motor 1 thrust.
0001 = minimum force.
0010 =maximum force.
BA230