Fuel supply
Injector supply
LUBRICATION CIRCUIT
Type of lubrication
Circuit fuel supply
Oil change including filter
(standard sump)
Oil quantity at minimum level
(standard sump)
Oil quantity at maximum level liters (kg)
Oil pressure at minimum
speed (with started engine)
Alarm for oil pressure too low bar
Oil cooling
COOLING CIRCUIT
Total capacity of the cooling
circuit (excluding radiator and
relevant pipes)
Setting pressure of the
expansion tank plug
Coolant
Opening value (start/finish) of
thermostatic valve
Coolant maximum temperature
alarm
ELECTRIC SYSTEM
Nominal voltage
Alternating current generator
(nominal voltage)
Alternating current generator
(nominal current)
Starter motor output
Recommended battery
capacity
Battery breakaway current
SUCTION CIRCUIT
Maximum depression allowed
with new air filter
English
D754SE3
Mechanical rotary injection pump
liters (kg)
liters(kg)
7 ÷ 10
The oil quantity at maximum level ( 7÷10 litre) depends
on the capacity of the oil sump with which the engine is
bar
liters
5
bar
1
50% demineralised or distilled water and 50% Petronas Paraflu
Up (protective radiator fluid with monoethylene glycol and organic
inhibitor formulation complying with ASTM D 3306 type 1 Standards)
°C
80 ± 2 / 95
°C
107
V
12
V
14
A
55
kW
2,3
Ah
92
A
480
mbar
15
29
D700-750E2_E3
D754TE3
Diaphragm pump
Forced lubrication
Rotor pump
7 ÷ 10
equipped.
1,2 ÷ 1,6
0,4
Oil/water cooler
5
1
80 ± 2 / 95
107
12
14
70
2,3
110
880
15
VM p/n 42432097F Ed.4 - 2015-05
D754IE3
GB
7 ÷ 10
5
1
80 ± 2 / 95
107
12
14
70
2,3
110
880
15