Maintenance during running-in (first 50 hours)
GB
For each maintenance operation, fill in
the "Periodic maintenance operation
record sheet" provided, so as to keep a
Frequency
(1)
Every 10
hours (Every
day)
After the
first 50 hours
(at the end of
running-in)
English
Type of inter-
Component
vention
Engine oil (2)
Level control
Coolant (4)
Level control
Check it is
clean
Air filter
Coolant fluid
Check it is
radiator
clean
Engine oil (2)
Replacement
Oil filter (3)
Replacement
Checking the
tension
Transmission
belt (5)
Integrity control
D700-750E2_E3
trace of the operations performed and
therefore establish the most suitable
methods for future operations.
Intervention
procedures
Top up, if nec-
essary
Top up, if nec-
essary
Clean with low
pressure com-
pressed air.
Clean with a
soft brush
Tension belts
Replace, if nec-
essary
50
VM p/n 42432097F Ed.4 - 2015-05
Reference
See Engine oil
level control
See Engine
coolant level
check
See Engine oil
change
See Oil filter
cartridge re-
placement
See "How to ad-
just the tension
of the driving
belt"
See "Belt re-
placement"