6 - DETAILED INSTALLATION
6.1. GONFIGURATION OF COOLING UNIT
The MIG welding torch is connected to the front of the wire feeder, after ensuring it has been properly outfitted with the wear parts corresponding to the
wire used for welding. Refer to the torch instructions.
If you use a water-cooled torch, make sure to connect your cooling unit to the rear of the power source, as well as to the water harness. Then, make sure
the torch is correctly selected:
In the menu: Configuration > Installation > Cooling system, set the value associated to the parameter: 'cooling selection'
With = Automatic functioning
Without = Stopped functioning to use an air-cooled torch
Always ON = Continuous functioning since start up of the power source.
Water fault: Activate or not the water warning of the cooling unit in function of the presence of the relevant captor.
Tm inhibition of water fault (s): Inhibition timing before activating a water fault added to the 12 seconds which are counted down by default after the start-
up of the cooling unit. Fault input level: Reverse the sense of warning detection of the cooling unit (to be adapted to most of the existing unit)
Inhibition default water time:
By default, the water default event trigger happens 12 seconds after the start of the cooling unit.
The inhibition of water default time adds a delay of 0 to 50 seconds to the 12 seconds set by default
User interface
Language - Time and date - Name
Post-display welding
Backlight
Administrator session time
Screensaver
Installation
General
Inverter
Wire feeder mode
Automation
Potentiometers
Cycle
Trigger short clicking time(s)
Hotstart during the 1st ON time only
Program call by trigger out of welding
Shorten downslope control
Fault
Process control fault type
Arc outage default
I feedback output type
Automation fault output level
Cooling unit
Cooling selection
Water fault
Inhibition time of water fault
32
Page 10
Setting of the post-display timing of the welding parameters
Setting of the Backlight of the power source screen
Setting of the timing before user log out
Setting of the timing before screensaver activation
Power of the power source inverter
Choice of the unique or several used wire feeders
Activation of MIG – Automation mode
Connection of potentiometers to the wire feeder cf Instruction of the wire feeder
Setting of the maximum trigger press delay to consider as a short press [0.1 ; 0.5]
In mode intermittent, a hotstart on the 1st time ON only
Activation of program calling out of welding
Allows shortening downslope by a short trigger press
Page 29
Activation of the detection of the arc voltage fault (in automatic mode)
Output type of the N1 intensity feedback regarding the evolution of the arc current. (en mode
autre)
Setting of the output level of the fault signal. (in automatic mode)
Air or Water.
Activation of the Water fault on the cooling unit if the relevant sensor exists. (option)
Adjusting the delay before triggering the water fault when the cooling unit starts(si défaut
actif)
.
DIGIWAVE II