Air Liquide SAF-FRO DIGIWAVE II 420 Manual Del Usuario página 43

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 208
Overtaking of the duty cycle of the power source
Only in AUTOMATIQUE mode
Only in AUTOMATIQUE mode
Calling a non existing program or unauthorized
The program is not compatible with this software version
The configuration is not compatible with this software version
A program is corrupt :
This program is visible in the list of programs on the screen on the front
of the generator.
The system configuration is corrupted
A list of programs is corrupted
The power supply is unstable
Impossible to finalize the automatic calibration.
Demand immediate cessation of welding user
More communication with a device
Problem of pressure or flow of cooling unit
MMA only :
Detection of stuck wire on the piece.
MIG only
Detection of the sticking of the wire in the workpiece.
Excessive engine torque unwinding
Launch welding program whose synergy user is not present in the welding
generator
Overflow monitoring threshold low welding current user-defined
Overflow monitoring threshold low welding current user-defined
DIGIWAVE II
DISPLAY OF THE MESSAGE E25 "Overtaking duty cycle"
DISPLAY OF THE MESSAGE E30 "Boot Failure"
DISPLAY OF THE MESSAGE E32 "Broken arc"
DISPLAY OF THE MESSAGE E33 "Job problem"
DISPLAY OF THE MESSAGE E42 «
DISPLAY OF THE MESSAGE E44 "Harness calibration problem"
DISPLAY OF THE MESSAGE E45 « order immediate stop welding»
DISPLAY OF THE MESSAGE E49 « Check Device Connection»
It is imperative to connect and disconnect the device when the system is off
DISPLAY OF THE MESSAGE E50 "Cooling problem"
DISPLAY OF THE MESSAGE E52 "Stuck electrode"
DISPLAY OF THE MESSAGE E53 "Stuck wire"
DISPLAY OF THE MESSAGE E63 « Excess torque reeling»
DISPLAY OF THE MESSAGE E72 "Not present synergy"
DISPLAY OF THE MESSAGE E80 « Detection Process Control I min »
DISPLAY OF THE MESSAGE E81 « Detection Process control I max »
Let the generator cool off
time out of 3 seconds Effective Detecting the welding launch without striking
break detection arc
Please update the software generator.
Please update the software generator.
Suppression program is necessary
Parametrage a new installation is required.
Please reconfigure the program listings
»
stable supply
please check your electrical system
Check that the calibration procedure displayed on the screen is well
respected
Check the device connection displayed
Unstick the electrode
Cut the wire
check that the sheath of the wire is not encrasse and that nothing prevents the
movement of the thread and the movement of the wire feed
import or define the corresponding user synergy current program
43

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Saf-fro digiwave ii 520W000371924W000371927

Tabla de contenido