en | AHT Cooling Systems GmbH
Specialists
– Only qualified staff authorised by AHT may carry
out the following work on the appliance:
– Main cleaning
– Maintenance, service, and repairs
– Only specialists trained in flammable refrigerants
may work on the refrigerant circuit of R-290 units.
– Only qualified electricians may carry out work on
the electrical system.
Persons (including children) with limited physical,
sensory, or mental abilities may only operate the appli-
ance under supervision and after training, and may not
carry out any maintenance work. Children must not
play with the appliance.
Work under the influence of alcohol and drugs is pro-
hibited.
2.4
Personal protective equipment
Use hand protection
– Protection against heavy equipment parts during
transport, unpacking, installation and disposal.
– Protection against sharp edges, rotating parts and
hot surfaces during maintenance and repair work.
– Protection against contact with liquid/leaking refri-
gerant in case of leakage of the refrigerant circuit.
– Protection against low temperature during loading
and cleaning.
– For removing glass parts and glass splinters in the
event of glass breakage.
– For the removal of parts in the event of material
breakage.
Use eye protection
– Protection against contact with liquid/leaking refri-
gerant in case of leakage of the refrigerant circuit.
2.5
Specific hazards
2.5.1 Electrical voltage
Only qualified staff may carry out work on the electrical
system.
In case of fault messages or damage to the device,
contact maintenance service (see →Maintenance ser-
vices).
WARNING
Contact with live parts may result in
electric shock.
Fire hazard due to sparking or overload.
▪ Do not connect a damaged device or dam-
aged parts (such as connecting cables) to
the power supply.
▪ Check to ensure safety devices are com-
plete and working.
▪ Do not remove protective devices and cov-
ers attached to the appliance.
▪ Before connecting to the power supply, ob-
serve the following:
- Applicable local electrical safety regula-
tions.
- Applicable standards and safety instruc-
tions.
405861_1_0819
Personal protective equipment | 2.4
- Information on the rating plate (see →
Rating plate and serial number).
- Mains voltage and mains frequency must
match the information on the rating plate.
▪ Only previously trained staff may cut power
of the device.
▪ Observe the following safety rules if the ap-
pliance is damaged during operation or
prior to maintenance:
1. Disconnect the appliance (switch off all
sources of electrical power).
2. Secure the appliance against reconnec-
tion.
▪ Only qualified staff may replace damaged
parts, e.g. connecting cables.
▪ Do not squeeze or bend the mains power
cable.
▪ Do not use extension cords or multiple
socket strips.
▪ Do not use steam or high-pressure clean-
ers for basic cleaning.
▪ Do not damage concealed electrical parts.
The operator must not drill into the appli-
ance or carry out any other work on it.
2.5.2 Refrigerant circuit
Only qualified personnel may carry out work on the re-
frigerant circuit.
In case of fault messages or damage to the device,
contact maintenance service (see →Maintenance ser-
vices).
Flammable refrigerants
WARNING
The refrigerant is highly flammable. If
leaks occur, refrigerant can escape
and cause an explosive gas/air mix-
ture.
This can result in fire and explosion with a
subsequent fire risk.
▪ Refrigerant R-290 (propane) is classified in
safety group A3 according to EN 378-1.
The refrigerant used and the filling quantity
can be seen on the rating plate (see →Rat-
ing plate and serial number).
▪ Keep away from sources of ignition (heat,
sparks, open flames, hot surfaces).
▪ Use a damp cloth or sponge to remove
condensation and for cleaning. Do not use
dry cloths or sponges to rub dry. (Risk of
electrostatic charge and sparking).
▪ Do not close the ventilation openings in the
unit housing. Only use original accessories.
▪ Do not use any mechanical devices or
other means (e.g. ice scraper) to acceler-
ate the defrosting process.
▪ Do not operate any electrical devices (e.g.
wet vacuum cleaners) inside the cooling
compartment that do not correspond to the
design recommended by the manufacturer.
Devices with explosion protection markings
(see → Explanation of symbols) are permit-
ted.
27 / 478