System programing: Read all of these steps before proceeding.
Each step must be followed exactly to properly program the control system.
1. You can leave the frequency switches at the factory setting or move them to any combination of up or
down. Use a small flat bladed screwdriver to move the switches.
2. Insert both batteries and make sure they are seated correctly in each recess with the positive + sign
facing up. Replace the battery cover. (Figure 21)
3. Test the transmitter by pushing and releasing ANY button briefly. A Blue Light should illuminate under
the 3-4 buttons. (Fig. 23) If not, check to make sure the batteries are inserted and seated correctly.
Power Up and Programming:
4. Follow the below steps to set the remote control:
The auto learning function will only mandate within 60 seconds when turning the fan's AC power ON.
(Figure 24)
5. Select desired frequency from the back of transmitter.
6. From the back of the transmitter, press and hold the "hold " button for 5+ seconds. Once the receiver
has detected the frequency, the light will flash twice, and the fan will automatically begin to operate
and start to rotate in the counter clockwise direction and on the highest RPM for 3 minutes. When
counterclockwise rotation has finished, the fan will automatically reverse to clockwise direction again
to the highest RPM for 3 minutes. Fan will shut off when the self calibration test has finished. The total
self calibration test will last about 6 minutes.
NOTE: If the self calibration test failed, turn the AC power off; restore power and process the self
calibration test again.
NOTE: During self calibration test, the remote is non-fuctional.
NOTE: The learning frequency function and self calibration test will continue to retain the last set
frequency and calibration set even when the AC power is shut off. If the frequency is changed the self
calibration test will occur again.
7. Your CoolTouch™ Control System is now programmed and ready for use. Please see the Operating
Instructions.
The receiver provides the following protective function:
1. Lock position: The DC motor has a built-in safety against obstruction during operation. If there is an
obstruction, the motor will stop and then the power will automatically go off in 30 seconds. Remove
the obstruction and reset.
2. Over 80W protection: When the receiver detects motor power consumption which is greater than
80W, the receiver power will be stopped and operation will immediately discontinue. Wait for 5 seconds
and then turn the receiver power back on.
18
| KICHLER.COM
Blue Light
Press/hold
Button
Fig. 23
Fig. 24