SATA LAB Automatic Gun Operating Instructions
EN
Warning!
If maintenance work is performed
while the gun is still connected
to the compressed air circuit and
material supply, components can
unexpectedly work loose and
material can leak.
→ Before performing any mainte-
nance work, drain the automatic
gun, switch it off, disconnect it
from the compressed air circuit
and drain the gravity flow cup.
Attention!
Incorrect assembly can cause
damage to the automatic gun.
→ Fix the automatic gun on a flat
surface before all kinds of main-
tenance work.
→ Make sure that threads fit prop-
erly.
→ Grease all moving parts with
SATA high performance grease
(Art. No. 48173).
Loose screws can cause damage
to parts or result in malfunctions.
→ Tighten all screws by hand and
check that they are screwed tight.
Use of the wrong tool can dam-
age the automatic gun.
→ Only use the special tool sup-
plied by SATA.
Springs and small parts can fall out
during dismantling. The precise
installation position and installation
sequence is shown in the figures.
106
All manuals and user guides at all-guides.com
Failure to comply can cause dam-
age to the parts or result in mal-
functions.
Spare parts are available for carry-
ing out repairs (see chapter 13).
10.1. Replacing the nozzle
set
The nozzle set consists of a tested
combination of paint needle [5-7],
air cap [5-9] and fluid tip [5-8]. Al-
ways replace the complete nozzle
set.
Dismantle the nozzle set
■ Unscrew the regulating cap [5-1].
■ Remove washer [5-2] and spring
[5-3].
■ Unscrew the end cap (spanner size
24) [5-4].
■ Remove both springs [5-5], [5-6].
■ Remove paint needle [5-7].
■ Unscrew air cap ring [5-10] by hand
and remove together with the air cap
[5-9].
■ Unscrew fluid tip [5-9] using the SATA
universal spanner.
Fit new nozzle set
Attention!
The components can be dam-
aged if fitted in the wrong order.
→ Always fit the fluid tip before
the paint needle.