SATA LAB Automatic Gun Operating Instructions
EN
Malfunc-
tion
Flat fan
control does
not work.
Flat fan
control
cannot be
regulated.
Automatic
gun does
not shut air
off.
Corrosion
on air cap
thread,
material
passage
or nozzle
head.
112
All manuals and user guides at all-guides.com
Cause
Correc-
tive ac-
Air distribu-
Put air
tion ring not
distribution
in correct
ring in cor-
position.
rect position
(see chap-
ter 10.2).
Air distri-
Replace air
bution ring
distribution
damaged.
ring (see
chapter
10.2).
Overwound
Remove
control.
spindle, un-
Loose spin-
lock and in-
dle.
stall again.
Replace
spindle if
necessary
(see chap-
ter 10.4).
Soiled
Clean con-
control
trol piston
piston seat
seat. Re-
or worn seal
place seal
retainer.
retainer if
necessary
(see chap-
ter 10.8).
Control air
Release
pressure is
control air
constantly
pressure.
present.
Unsuitable
Replace
cleaning
nozzle
solution.
head. Heed
cleaning
instructions
(see chap-
ter 10.3).
Malfunc-
Cause
tion
Air leaks
Defective
from inspec-
seal retain-
tion hole
er (air side).
of material
flow control
or regulat-
ing cap.
Defective
seal or
sleeve.
Material
Defective
leaks from
paint needle
behind
sealing
the paint
needle seal
through the
gun body
inspection
hole.
Paint nee-
dle clogged
or dam-
aged.
Automatic
Contam-
gun drips
ination
out of the
between
fluid tip.
paint needle
tip and fluid
tip.
Damaged
nozzle set.
13. Customer service and
spare parts
Customer service department
SATA GmbH & Co. KG
Domertalstraße 20
D-70806 Kornwestheim
Automatic gun spare parts
Correc-
tive ac-
Replace
paint needle
seal re-
tainer (see
chapter
10.3).
Replace
seal or
sleeve (see
chapter
10.7).
Replace
paint needle
seal re-
tainer (see
chapter
10.3).
Replace
nozzle set
(see chap-
ter 10.1).
Clean fluid
tip and paint
needle.
Replace
nozzle set
(see chap-
ter 10.1).