ORBIMAT 300 SW
Abb. 15:
Main menu (Short form)
1. Touch the login icon at the bottom right in the screen.
A virtual keyboard is displayed.
2. Enter the password and confirm by pressing the rotary knob.
X Login icon highlighted in blue = Logged in.
3. To log out touch the login icon at the bottom right in the screen.
X Icon highlighted in blue becomes gray = Logged out.
Initial password at the initial login: 12345
The password can be changed at any time under the menu item "System settings".
If the password is lost/forgotten, please use the machine-specific master password specified in the
calibration certificate. If logging in with the master password is not possible, please contact Orbitalum.
Limitation of the percentage current change
In the "disabled" position, the operator can not adjust or delete existing procedure sequences.
If it is necessary, however, to make small adjustments for a welding task (e.g. due to batch-based fluctuations of the
material composition or minor changes in the wall thickness), a percentage limit can be set in the welding procedure.
The operator can adjust the current within this limit.
This adjustment is not saved in the procedure and affects all sectors and the high-pulse and low-pulse current.
X Recommendation: Allow for maximum 10% (20% adjustment range).
Specifying "5%" means that it is possible to adjust up to 5% above or below the base value. The total adjustment range
amounts to 10%.
Specifying a limit
1. Locking the machine with a login
The main menu "Long form" appears in the display.
2. In the main menu, select "System settings" > "Program settings".
3. Select and highlight the "Scale weld limit" field and enter a percentage value.
– or –
If no adjustment is desired: Enter the value "0".
4. Save the procedure.
5. Lock the machine with a login.
(14.01.21) OW_ORBIMAT_300SW_BA _852060202_00_EN
The saved data are largely protected against loss or
change.
Recommendation
X Create backup copies of the data of the internal
memory at regular intervals.