G-ST 500+
Managing I/O contacts
Digital outputs
Adding I/O contacts in G-Set
Example
Using programmable and tamper-monitored digital inputs and outputs, con-
tacts for event-controlled recording can be controlled. For example, using a
contact the movement of a pan/tilt head can be triggered, a gate can be
opened or an infrared light can be switched on.
Each input and output can be given a meaningful name and an additional
description in the G-Set configuration software.
Each unit has four isolated digital outputs. Like the digital inputs, these are
distributed onto the 15-pin sub-D socket (relay 1-4).
Using the digital outputs, you can switch external devices, for example, to
report system errors. The events are created and set up accordingly in the
G-Set configuration software.
Similar to the cameras, I/O contacts must also be registered using the G-
Set software. The I/O connections are displayed in the list of hardware mod-
ules. Configuration is performed in a separate view.
1. In the General Settings section, select the entry IO Settings.
2. Using Add, open the list of I/O contacts.
The list also shows the I/O contacts.
3. Select the required inputs and outputs.