FVSD 2900
User instructions
FUNCTIONAL ANOMALY
The cycle does not start and
all control panel keys flash.
The luminous STOP key
flashes accompanied by an
intermittent acoustic signal.
On switch-on, all luminous
indicators on the control
panel flash for 3 seconds and
an acoustic signal is heard
(long beep).
The cycle starts (keys flash)
but the pump does not
start.
The machine does not switch
on.
2.007.98 .0 - R00 - 09/2018
TROUBLEShOOTING GUIDE
POSSIBLE CAUSES
Overheating, damage to the
electronic circuit.
Insufficient vacuum in the cham-
ber due to one of the following
reasons:
• Lid not pressed on cycle start-
up.
• Lid gasket worn or incorrectly
positioned.
• Leak from vacuum circuit.
• Faulty vacuum sensor.
• Clogged vacuum pump.
Warning that oil change is requi-
red as 2500 functioning cycles
have been performed.
Pump circuit breaker protec-
tion intervention due to over-
heating.
No energy.
SOLUTION
• Switch the machine off and
wait for about 15 minutes for
cooling and automatic restore
of the circuit breaker protec-
tions.
If the problem persists when
switched back on, call the af-
ter-sales technical assistance
to check the machine.
• Press the lid upon cycle start-
up.
• Check and eventually replace
the lid gasket.
• Call the after-sales technical
assistance to check the air
circuit.
• Call the after-sales technical
assistance to check the vacu-
um sensor.
• Call the after-sales technical
assistance to check the vacu-
um pump.
• Intervention of a technician to
replace the pump oil.
• Switch the appliance off and
wait about 15 minutes before
re-applying voltage.
• Check the connection to the
electric line.
85