English
The cut-off machine is now ready for
use.
Switching off the engine
Slide the master control lever (3) to
N
STOP or 0
Additional hints on starting
If the engine does not start
The choke lever was not returned to o
in time after the engine turned over for
the first time.
Move the master control lever to
N
START = starting throttle position
Set the choke lever to e = warm
N
start, even if the engine is cold
Pull the starter rope through 10-20
N
times to ventilate the combustion
chamber
Restart the engine
N
If the tank has been drained completely
Refueling
N
Press the manual fuel pump bulb
N
7-10 times – even if it is full of fuel
36
Set the choke lever in accordance
N
with the engine temperature
Restart the engine
N
Air Filter System
Basic information
The average filter life is more than 1
year. Do not dismantle the filter cover or
fit a new air filter unless there is a
noticeable loss of engine power.
In the long-life air filter system with the
cyclone pre-separation system, dirty air
is drawn in and deliberately rotated. The
larger and heavier particles carried in
the air are thus expelled and extracted.
Only pre-cleaned air enters the air filter
system and the result is extremely long
filter life.
Replacing the air filter
Only if there is a noticeable loss of
engine power
4
2
1
3
Remove the locking screw (1) on
N
the filter cover
Remove the filter cover (2)
N
Remove all coarse dirt from the area
N
around the filter and the inside of the
filter cover
TS 700, TS 800