MAINTENANCE
Troubleshooting
Display
Condition
Green
Low
Motor
Pressure
Frequency
Green
High
Motor
Pressure
Frequency
Green
Audible
Motor
Noises
Frequency
No Display
None
FE Connect
Light On
Soid
Cannot Con-
nect to Drive
Bluetooth
FE Connect
Light Off
Green
RFI-EMI
Motor
Interference
Frequency
System Reg-
ulates but
Green 199P
displays
199P
54
Possible Cause
Pressure sensor setting,
pump rotation, pump sizing
High temperature
Pressure sensor setting
Shorted sensor wire
Fan
Hydraulic
Plumbing
Display board cable discon-
nected or loose
Attempting to connect to
incorrect drive
Out of Wi-Fi range of drive
(more than 100 ft line-
ofsite)
Wi-Fi timeout expired
Poor grounding
Wire routing
The pressure in the system
is 199 psi or higher
Corrective Action
Adjust pressure sensor, check pump rotation.
Check frequency at max flow, check max pressure
High ambient and/or drive temperature will cause drive to fold-
back power and run with reduced performance
Adjust pressure sensor
Verify condition of sensor wire and repair.
Remove sensor wire at Pressure Input Board.
1. if drive stops running, wire may be shorted
2. if drive continues to run, replace Pressure Input Board
3. If drive continues to run after replacing Pressure Input board,
replace drive
For excessive fan noise, replace fan
If fan noise is normal, drive will need to be relocated to a more
remote area
If a hydraulic problem, try raising or lowering depth of pump
Pressure tank location should be at entrance of water line into
house
Verify cable connection between main control board and display
Ensure the Wi-Fi SSID (hotspot name) you are connecting to
matches the correct drive
Move so Wi-Fi signal is closer to the drive if walls or floors are
between you and the drive
Wi-Fi module not responding, cycle power to drive
Cycle Wi-Fi radio on mobile device, refresh Wi-Fi connection list
If more than fifteen (15) minutes since last power cycle, cycle
power to drive
If more than one (1) hour since last disconnection from Wi-Fi,
cycle power to drive
Adhere to grounding and wire routing recommendations
An additional external filter may be needed.
The max pressure the display can show is 199 psi. Use the pres-
sure gauge or Wi-Fi / FE-Connect app to view the system
pressure.