Descargar Imprimir esta página

Corghi ET 1450 Manual De Uso página 101

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

- Move the end of the automatic measuring arm in line with the plane selected for the
application of the inner weight. In ALU1P (fig.16), the reference of the weight mid-point
is the centre of the disc (fig.15a). In ALU2P you must refer to the rim edge, because the
inner weight is of the spring type (fig.17).
- Keep the arm in position. After two seconds the machine emits an acoustic confirmation
signal to indicate that the distance and diameter values have been acquired.
- bring the end of the automatic measuring arm in line with the plane selected for the
application of the outer weight (fig. 16a/17a) (following the procedure described above,
for the inner side).
Pay maximum attention when the end of the arm is being placed in an area of the
rim free of discontinuity, so that the weight can be applied in that position.
- Keep the arm in position. After two seconds the machine emits an acoustic confirmation
signal to indicate that the distance and diameter values have been acquired.
- Return the measuring arm to the rest position.
Automatically the machine will set up in the ALUP balancing programmes (FSP pro-
gramme).
- carry out a spin
- at the end of the spin, if you want to change the balancing programme set automatically
by the machine (FSP), use the
Operator's Manual ET 1450
or
key to select the required programme.