Descargar Imprimir esta página

Corghi ET 1450 Manual De Uso página 130

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

The automatic arm laser line does not work (if present)
To replace the battery, proceed as follows:
➥ Remove the four screws in the lever (A,
Fig.24) and then remove the plastic cas-
ing (B, Fig.24)
➥ Pull out the card (C, Fig.24) inside
➥ Replace the battery in the card with a
new CR2450 3V;
➥ Continue to mount the lever in the oppo-
site direction to disassembly.
CAUTION
Pay attention to the positioning of the
cables inside the lever groove to prevent
accidentally damaging the cable while
closing the plastic crankcase.
If the laser line does not work with the new battery, call for technical assistance.
The wheel does not move (machine does not start)
when the launch spin button is pressed
On motorised version of machine, check that both buttons (D and I, fig.4) are pressed
correctly.
The wheel balancer provides unsteady unbalance values
The machine was jolted during the spin.
Repeat the spin, taking care not to disturb the machine while measuring is in progress.
The machine does not firmly rest on the floor.
Make sure that the floor support is firm
The wheel is not locked correctly.
Tighten the securing ring nut correctly.
Several spins are to be performed to balance the wheel
The machine was jolted during the spin.
Repeat the spin, avoiding any unnecessary strain during the acquisition procedure.
The machine does not firmly rest on the floor.
Make sure that the floor support is firm.
The wheel is not locked correctly.
Tighten the securing ring nut correctly.
The machine has not been calibrated correctly.
Carry out the sensitivity calibration procedure.
The entered geometric data are not correct.
Check that the data corresponds to the dimensions of the wheel and correct, if necessary.
LED light and/or laser indicator are NOT working
check if the device(s) is (are) configured correctly as shown in the paragraphs "SET UP
- LED light " and "SET UP - Laser indicator". If the problem persists after checking the
correct device configuration, call the technical support centre.