14. MEMORY SWITCH
(1) Operating procedure
(2) Memory switch list
No.
Function
1
Soft-start speed setting
1st stitch (Inside needle → outside needle)
2
Soft-start speed setting
1st stitch (outside needle → inside needle)
3
Soft-start speed setting
2nd stitch (inside needle → outside needle)
4
Soft-start speed setting
2nd stitch (outside needle → inside needle)
5
Soft-start speed setting
3rd stitch (inside needle → outside needle)
6
Soft-start speed setting
3rd stitch (outside needle → inside needle)
7
Needle thread tension setting at the time of
thread trimming
8
Looper thread tension setting at the time of
thread trimming
9
Needle thread tension setting at the time of
machine-stop
10
Looper thread tension setting at the time of
machine-stop
11
Set position selection
Origin position/Front
12
Production counter selection
Without/UP/DOWN
13
Selection of starting when production
counter is "0"
Permitted/prohibited
68
1) Select memory switch No. with [LEFT
or [LEFT
2) Change the set value with [RIGHT
[RIGHT
3) Repeat the steps 1) to 2) when changing other set values.
4) After completion of setting, press [READY
key
the memory switch mode ends.
Description
Limited speed at the sewing start of the sewing machine
is set. From inside needle to outside needle of 1st stitch
Limited speed at the sewing start of the sewing machine
is set. From outside needle to inside needle of 1st stitch
Limited speed at the sewing start of the sewing machine
is set. From inside needle to outside needle of 2nd stitch
Limited speed at the sewing start of the sewing machine
is set. From outside needle to inside needle of 2nd stitch
Limited speed at the sewing start of the sewing machine
is set. From inside needle to outside needle of 2nd stitch
Limited speed at the sewing start of the sewing machine
is set. From outside needle to inside needle of 3rd stitch
Needle thread tension value at the time of thread
trimming is set.
Looper thread tension value at the time of thread trimming
is set.
Needle thread tension value at the time of machine-stop
is set.
Looper thread tension value at the time of machine-stop
is set.
Position of presser when setting cloth is selected.
0 : Origin position
1 : Front position (Position is set at No. = 29.)
Operation of production counter is selected.
0 : Without
1 : UP counter (" + 1" per sewing cycle)
2 : DOWN counter (" − 1" per sewing cycle)
Whether prohibiting starting at count value "0" when
production counter is set to DOWN counter is selected.
0 : Starting permitted even when production counter
value is "0"
1 : Starting prohibited when production counter valueis "0"
Pressing [READY
] key
power and the mode becomes the memory
switch mode. Then various data can be changed.
] key
.
] key
.
to make the set value store in memory and
When [RESET
] key
mode ends without storing the set value
in memory. When turning OFF the power
without pressing [READY
setting is not stored in memory.
Setting
range
400 to 1,200
400 to 2,200
400 to 2,200
400 to 2,200
400 to 2,200
400 to 2,200
0 to 255
0 to 255
0 to 255
0 to 255
0 to 1
0 to 2
0 to 1
, turn ON the
] key
] key
or
]
is pressed , the
] key
, the
Setting
Initial
unit
value
100
600
sti/min
sti/min
100
600
sti/min
sti/min
100
600
sti/min
sti/min
100
600
sti/min
sti/min
100
600
sti/min
sti/min
100
600
sti/min
sti/min
1
0
1
0
1
60
1
0
-
0
-
1
-
1